WORKOVER RIGS

XJ350 Battery energy storage workover rig

Field notes for XJ350 Battery energy storage workover rig: hook load, mast arrangement, mobility and the workover conditions that shape final equipment selection.

XJ350 Battery energy storage workover rig

Product parameters

Max. Hook load900 kH
Drive type8x8
Mast height21m
Motor power160 kW
Battery capacityy150 kwh
Automation efficiency35~40 columns/hour
Workover Rigs

Technical profile

In response to the limited operation caused by limited capacity of well site transformers, we have developed XJ350 electric workover rig, with power coming from 30KVA well site transformer plus battery storage energy in the case of rig operation, and from the chassis engine in the case of rig movement.

At a glance

Key specifications

Drive type8x8
Mast height21m
Motor power160 kW
Battery capacityy150 kwh

The available technical data for XJ350 Battery energy storage workover rig covers Drive type, Mast height, Motor power, Battery capacityy, Automation efficiency. Use these fields to compare the listed configuration with the project duty, site interface and delivery requirements before requesting a final quotation.

Workover RigsXJ350 Battery energy storage workover rigoilfield equipmentfield service
Request technical details ?
Specification review

Confirm the workover rig equipment duty for XJ350 Battery energy storage workover rig before quotation.

XJ350 Battery energy storage workover rig is intended for well servicing, workover, completion support and intervention operations. Review the actual well program, site interface and operating environment before approving a final technical configuration.

Parameter confirmation

  • hook load, working height and wellhead interface
  • mast, drawworks and power arrangement
  • transport, rig-up and location constraints
  • climate, terrain and maintenance conditions

Configuration selection

  • mast and substructure selected around the workover program
  • drive and control package matched to site power
  • truck, trailer or modular arrangement reviewed
  • wellhead and auxiliary systems coordinated

The current product record provides these technical fields for review: Drive type, Mast height, Motor power, Battery capacityy, Automation efficiency. Match the listed values with the required duty point and request confirmation for any interface or operating condition not shown.

Engineering context

What to confirm before quotation.

Workover selection depends on hook load, mast height, mobility, power source, wellhead clearance, site access and service cycle.

Mobile Workover ServiceCompare truck, trailer, skid or integrated layouts against transport limits, rig-up time and available utilities.
Desert And Remote FieldsConfirm temperature, altitude, corrosion exposure, access and maintenance conditions before freezing the specification.
Battery, Electric And Conventional Drive OptionsConfirm temperature, altitude, corrosion exposure, access and maintenance conditions before freezing the specification.
Quality and documentation

Request the workover evidence package for XJ350 Battery energy storage workover rig.

For XJ350 Battery energy storage workover rig, quality and delivery review should be tied to the final configuration rather than general claims. Ask for the applicable inspection scope, dimensional information, test records and supplied documentation before purchase approval.

Quality review

  • Confirm the inspection points, test scope and acceptance documents applicable to the ordered configuration.

Technical materials

  • Request the workover rig datasheet for this model.
  • Request the GA and transport drawing for this model.
  • Request the mast and drawworks configuration list for this model.

Delivery readiness

  • Confirm package dimensions, lifting or transport requirements, installation interfaces and the documents supplied with delivery.
Buyer questions

Questions to settle before purchase.

What hook load and mast height are required?

For XJ350 Battery energy storage workover rig, the table above confirms Mast height: 21m. Use that figure as the baseline and verify the final duty cycle, safety margin and installation interface before release.

Which drive and transport configuration fits the site?

For XJ350 Battery energy storage workover rig, the configuration must match transport limits, rig-up time, power availability and maintenance access. Confirm the preferred mounting form before final quotation.

What automation or energy-storage option is needed?

For XJ350 Battery energy storage workover rig, the available data sheet covers Drive type, Mast height, Motor power, Battery capacityy. Share the job conditions, interface dimensions and delivery location so the configuration can be checked against the project requirement.

Direct inquiry

Send the XJ350 Battery energy storage workover rig requirement.

For XJ350 Battery energy storage workover rig, include the model, application, required duty, quantity and delivery destination. For a faster technical response, also include the hook load, working height and wellhead interface; mast, drawworks and power arrangement; transport, rig-up and location constraints.

Request product details
Configuration support

Need a different workover mast or transport form for XJ350 Battery energy storage workover rig?

Share the hook load, working height, location access and site power. We will help narrow the workover package before quotation.